Capsule Hyperbaric Oxygen Chamber (Horizontal)
Compact footprint for rooms with limited space
- Pressurisation 0–150 KPa, piston or scroll compressor
- Oxygen output 5 / 10 / 15 / 20 L, customisable
- Separate supply unit: 570 × 570 × 1450 mm, ≤75 kg
Commercial terms depend on configuration and order quantity. Each value below is confirmed in the quotation.
Overview
Horizontal capsule shell φ810 × 2200 mm in Q345 carbon steel or aluminium alloy, 220 kg depending on configuration. The separate supply unit measures 570 × 570 × 1450 mm and is ≤75 kg. Oxygen delivery pressure is ≥0.15 MPa at 93% ±3%, with output of 5, 10, 15 or 20 L/min depending on configuration. Pressurisation range 0–150 KPa; compressor safety pressure 200, 250 or 300 KPa. Operating environment -10°C – 40°C, noise below 55 dB. This product is a pressure and oxygen-delivery device and is not a medical device for diagnosis or treatment of disease.
Specifications
Certificates on file cover the tested configuration. Certificate scope and validity are stated in the quotation.
chamber
| Chamber dimensions | φ810 × 2200 mm |
|---|---|
| Chamber weight | 220 kg (config-dependent) |
| Shell material | Q345 carbon steel or aluminium alloy |
mainUnit
| Main unit dimensions | 570 × 570 × 1450 mm (L×W×H) |
|---|---|
| Main unit weight | ≤75 kg (config-dependent) |
| Power supply | 220V / 50Hz |
| Rated power | 1600VA / 2700VA / 3500VA |
| Fuse rating | 16A / 25A / 32A |
| Oxygen flow | 5 / 10 / 15 / 20 L, customisable |
| Oxygen concentration | 93% ±3% |
| Oxygen pressure | ≥ 0.15 MPa |
| Operating environment | -10°C – 40°C |
| Noise | < 55 dB |
pressurisation
| Pressurisation flow | 100/130/150/220 L/min (piston) · 440/1000 L/min (scroll) |
|---|---|
| Pressurisation range | 0–150 KPa |
| Compressor safety pressure | 200 / 250 / 300 KPa |
control
| Display | 7-inch LCD touch panel |
|---|---|
| Functions | Oxygen generation, pressurisation, timer |
| Additional | Intermittent / continuous air exchange |
Procurement data
Commercial terms depend on configuration and order quantity. Each value below is confirmed in the quotation.
Compliance
Certificates on file cover the tested configuration. Certificate scope and validity are stated in the quotation.
Certificate on file. Applicable directives and the notified body reference are confirmed per order.
File reference LTC230913-CSA-035. Covers the tested configuration; re-testing is quoted if the configuration changes.
File reference LTC230913-CSA-034. Covers the tested configuration; scope is confirmed per order.
Quality management system for design, manufacture and service. Certificate number and validity on request.
Environmental management system. Certificate number, scope and validity on request.
Occupational health and safety management system. Certificate number and validity on request.
Documentation
Catalogues and certificates are available as PDF. Request the current file revision with your enquiry.
O2AKSO Product Catalogue (EN)
Full English line sheet with specifications and chamber options.
Download catalogCompany Profile (CN / EN)
Who we are, manufacturing base, R&D and quality systems.
Download catalogFrequently asked questions
The questions overseas procurement teams ask us most often, answered without marketing language.